TOPéa ULTRA THIN, ULTRA INSULATING, THE INFILL PANEL ULTRA LIGHT !

Application

For new builds and renovation projects
Tertiary: educational establishment, office, local government premises, public building, etc.

Technical

With an insulation capacity 5 times higher than rock wool, TOPéa revolutionizes the thermal insulation on the façade.
With a thickness of 24 mm, TOPéa is ultra slim and becomes an ultra lightweight infill panel that allows saving time during installation.
This ultra lightweight infill panel replaces 100 mm of rock wool and reaches a Up coefficient of 0,3.
Both technical and aesthetic, TOPéa is available in all the external claddings proposed by EA FAÇADE : (glass, sheet metal, laminate).
A modern design for an optimal thermal insulation.

Installation

Beaded on 4 sides. Horizontal or vertical frame system.
Do not drill the panel.
Consult CSTB specification No. 3075 for information about the general terms and conditions applicable to the installation of infill panels.
TOPéa complies with the requirements of CSTB specification No. 3076.

External cladding :

  • tempered enamelled glass (reflective or screen-printed)
  • aluminium sheet metal (raw, anodized, pre-lacquered or post-lacquered)
  • galvanized steel sheet metal (raw / pre-lacquered or post-lacquered)
  • melamine laminate

Internal cladding :

  • galvanized steel sheet metal (raw, pre-lacquered or post-lacquered)
  • aluminium sheet metal (raw, anodized, pre-lacquered or post-lacquered)

Insulating core  :

  • ultra thin I=insulation (=0.007 W/m*K)

Frame :

  • treated wood (standard or rebated)

TECHNICAL SPECIFICATIONS

Dimensions

Maximum format :

  • Steel sheet metal 4000 x 1500 mm
  • Aluminium sheet metal 4000 x 1500 mm
  • Enamelled glass (thickness: 6 mm) 3000 x 2000 mm, (thickness: 8 mm) 4000 x 1900 mm
  • Melamine laminate 2500 x 1250 mm

Thermal insulation

Formula for calculating the U value (according to CSTB and based on the recommendations of the NRT)

U*(Wm2K) =

1

+ 0,05 

P

 

0,17 + C1 e1 + R

 

S

R = thermal resistance of the insulating

P = perimeter of the panel (ml)

S = panel surface (m2)

e1 = backing panel thickness (cm)

C1 = thermal resistance of the backing panel for 1 cm

* Replaces the K coefficient, according to NRT

Acoustic insulation

ALSA CB-E panels enhance the acoustic insulation of buildings. They comply with the regulations relating to the acoustic insulation of buildings against external noise in areas classified as IV, i.e., "unrestricted". Certified studies and tests can be performed, on request, for any project with specific acoustic insulation requirements.