Infill panel with external cladding in laminate for lightweight facades subjected to technical evaluation no.2/06-1199.
STRATéa complies with the requirements of CSTB specification No. 3076.
For new builds and renovation projects
Tertiary: educational establishment, office, local government premises, public building, etc.
Consult CSTB specification No. 3075 for information about the general terms and conditions applicable to the installation of infill panels.
External cladding : 3 mm laminate
Internal cladding :
Insulating core : extruded polystyrene or mineral wool
Frame :
Backing panel :
Formula for calculating the U value (according to CSTB and based on the recommendations of the NRT)
U*(Wm2K) = |
1 |
+ 0,05 |
P |
0,17 + C1 e1 + R |
S |
R = thermal resistance of the insulating
P = perimeter of the panel (ml)
S = panel surface (m2)
e1 = backing panel thickness (cm)
C1 = thermal resistance of the backing panel for 1 cm
* Replaces the K coefficient, according to NRT
ALSA CB-E panels enhance the acoustic insulation of buildings. They comply with the regulations relating to the acoustic insulation of buildings against external noise in areas classified as IV, i.e., "unrestricted". Certified studies and tests can be performed, on request, for any project with specific acoustic insulation requirements.
Panels comply with the regulation and requirements of CSTB specification No. 3076.